Ac-mer-con-mr52

Intelligent Single Door Controller

The Avigilon™ Access Control Manager (ACM)™ system supports open field hardware from Mercury Security allowing organizations to leverage investments in non-proprietary field hardware, with retrofit programs available for industry standard door hardware and card readers, including contact/contactless smart card, proximity, magnetic stripe and barcode.

The AC-MER-CONT-1DR is a powerful, intelligent controller solution for managing one or two on-board readers (expandable to 17 readers) with the Access Control Manager system from Avigilon.

Based on the Mercury Security EP1501, the ACMER-CONT-1DR communicates with ACM via its on-board PoE capable Ethernet port. The AC-MERCONT-1DR includes two inputs, two outputs and two reader ports and easily expands I/O and readers by simply adding input, output and reader interface modules. Easy installation with Power over Ethernet (PoE) makes this a top choice for a single controlled opening controller with ACM.

The Access Control Manager system and Mercury Security open field hardware provide the ultimate platform to complete the Avigilon end-to-end security solution.

ac-mer-con-mr52

KEY FEATURES

  • PoE capable intelligent network controller
  • Single-door interface that can expand to 17 reader doors
  • Suitable for in/out reader applications
  • Network ready
  • Decentralizes system intelligence
  • Triple gang footprint
  • Provides full local processing
  • Interfaces with a wide array of reader technologies including Wiegand, clock
  • and data, magnetic stripe and keypads
  • Support for up to eight device addresses through the on board RS-485
  • communication port
  • Support for the AC-MER-CON-MR50, AC-MER-CON-MR52, AC-MER-CONMR16IN and the AC-MER-CON-MR16OUT
  • Support for the AC-MER-CON-MR51E over Ethernet

Specifications

TECHNICAL SPECIFICATIONS
Power InputPoE Power Input 12.95W, compliant to IEEE 802.3af or 12 V DC ±10%, 200 mA minimum, 900 mA maximum power supply. Note: For UL installations, PoE powered devices shall not be used, power for these devices must be provided by an UL 294 listed power limited source (12 V DC).
Power Output12 V DC @ 650mA including reader and AUX output
Reader InterfacePowered by PoE (12 V DC +/-10%) or local power supply (12 V DC). (PTC limited 150mA max)
InputsTwo unsupervised/supervised, Programmable End of Line resistors, 1k/1k ohm, 1 %, ¼ watt standard
OutputsTwo relays Form C, 2A @ 30 V DC, resistive
Reader PortsReader port 1: TTL compatible, F/2F or 2-wire RS-485

Reader port 2: TTL compatible or F/2F

KeypadMultiplexed with card data
LEDTTL compatible , high > 3 V, low < 0.5 V, 5 mA source/sink maximum
BuzzerOpen collector, 12 V DC open circuit maximum, 40 mA sink maximum
Dimensions (W x L X H)140mm x 70mm x 24mm; 5.5” x 2.75” x 0.96” without bracket

140mm x 92mm x 34mm; 5.5” x 3.63” x 1.33” with bracket

TemperatureOperating: 0° C to 70° C (32° F to 158° F)

Storage: -55° C to 85° C (-67° F to 185° F)

Humidity5 – 95% Relative humidity (non-condensing)

 

TECHNICAL FEATURES
ConnectivityPrimary Port: 10/100 Ethernet
Door ControlOne physical barrier can be controlled using single or paired readers.

 

Two reader ports — Mag, Wiegand, or RS-485 (RS-485 on one reader port capable of supporting two readers). Two supervised inputs,

 

two relays. Diagnostic LEDs. Dedicated tamper input

Access Control• 145,000 cardholder capacity, 50,000 transaction buffer.

• 16 Access Levels per controller.

• 8 digit PIN number maximum

• Activation/Deactivation dates.

• If/Then Macro capability

Card FormatsEight active card formats per appliance — CAC, TWIC card compatible.

Anti-passback support — Nested area, hard, soft, or timed forgiveness.

Alarm ManagementNormally open/Normally closed, unsupervised, supervised. Standard or custom end-of-line resistances
StandardsUL294 Recognized, CE Compliant, RoHS, FCC Part 15 Class A, NIST Certified Encryption

 

ORDERING INFORMATION
AC-MER-CONT-1DRAccess Platform EP1501 Single Door Controller with PoE Support (Mercury EP1501)

 

ac-mer-con-mr52

 

Intelligent Two Door Controller

The Avigilon™ Access Control Manager (ACM)™ system supports open field hardware from Mercury Security allowing organizations to leverage investments in non-proprietary field hardware, with retrofit programs available for industry standard door hardware and card readers, including contact/contactless smart card, proximity, magnetic stripe and barcode.

ac-mer-con-mr52

The AC-MER-CONT-2DR is a powerful, intelligent controller solution for managing one or two on-board readers (expandable to 64 readers) with the Access Control Manager (ACM) system from Avigilon.

Based on the Mercury Security EP1502, the ACMER-CONT-2DR communicates with ACM via its on-board Ethernet port. The AC-MER-CONT-2DR includes eight inputs, four outputs and two reader ports and easily expands I/O and readers by simply adding input, output and reader interface modules. Offering powerful flexibility the AC-MER-CONT-2DR is capable of interfacing with a wide array of reader technologies for one or two controlled openings.

The Access Control Manager system and Mercury Security open field hardware provide the ultimate platform to complete the Avigilon end-to-end security solution.

KEY FEATURES

  • RS-485 intelligent controller that supports a variety of independent
  • functions
  • Two-door interface with auxiliary I/O that expands to 64 doors
  • Suitable for in/out reader applications
  • Decentralizes system intelligence
  • Network ready
  • Provides full local processing
  • Interfaces with a wide array of reader technologies including Wiegand, clock
  • and data, magnetic stripe and keypads
  • Onboard support for one or two controlled openings
  • Support for up to 31 device addresses through the on board RS-485
  • communication port
  • Support for the AC-MER-CON-MR50, AC-MER-CON-MR52, AC-MER-CONMR16IN and the AC-MER-CON-MR16OUT
  • Supports for the AC-MER-CON-MR51E over Ethernet

 

Specifications

TECHNICAL SPECIFICATIONS
Primary Power12-24 V DC +/- 10%, 500mA maximum
Serial PortsPrimary 10/100 Ethernet Port 2: RS-485, 2-wire
Reader InterfacePowered by PoE (12 V DC +/-10%) or local power supply (12 V DC). (PTC limited 150mA max)
InputsEight general purpose: programmable circuit type

Two dedicated: tamper and power monitor

OutputsFour relays: Form C, 5A 30V DC
Reader InterfaceReader Power: 12 V DC ±10% regulated, current limited to 150 mA for each reader.(jumper selectable) or 12 to 24 V DC ±10%

(input voltage passed through) current limited to 150 mA for each reader.

 

Data Inputs: TTL compatible inputs, mag stripe and Wiegand standards supported. Maximum cable length: 152 m (500 ft.).

RS-485 Mode: 9,600 to 38,400 bps, asynchronous, half-duplex, 1 start bit, 8 data bits, and 1 stop bit. Maximum cable length:

609.6 m (2000 ft.).

 

LED Output: TTL levels, high>3 V, Low<0.5 V, 5 mA source/sink maximum.

 

Buzzer Output: TTL levels, high>3 V, Low<0.5 V, Low=Active, 5 mA source/sink maximum

Cable RequirementsPower: 1 twisted pair, 18 AWG.

Ethernet: CAT-5, minimum.

RS-485: (I/O Device Port): 24 AWG, 1,219 m (4,000 ft.) maximum, twisted pair(s) with an overall shield. (Reader Port): 24 AWG,

609.6 m (2,000 ft.) maximum, twisted pair(s) with an overall shield.

RS-232: 24 AWG, 25 ft (7.6 m) maximum.

Alarm Input: 1 twisted pair, 30 ohms maximum, typically 22 AWG @ 304.8 m (1000 ft.)

Dimensions (W x L x H)152mm x 203mm x 25mm; 6.0” x 8.0” x 1.0”
TemperatureOperating: 0° C to 77° C (32° F to 170° F)

Storage: -55° C to 85° C (-67° F to 185° F)

Humidity10 – 95% Relative humidity (non-condensing)
StandardsUL294 Recognized, CE Compliant, RoHS, FCC Part 15 Class A, NIST Certified Encryption

 

TECHNICAL FEATURES
ConnectivityPrimary Port: 10/100 Ethernet
Door ControlTwo reader ports: Mag or Wiegand

Eight supervised inputs, four relays. Diagnostic LEDs

Access Control• 145,000 cardholder capacity, 50,000 transaction buffer.

• 16 Access Levels per controller.

• 8 digit PIN number maximum

• Activation/Deactivation dates.

• If/Then Macro capability

Card FormatsEight active card formats per appliance — CAC, TWIC card compatible.

Anti-passback support — Nested area, hard, soft, or timed forgiveness.

Alarm ManagementNormally open/Normally closed, unsupervised, supervised. Standard or custom end-of-line resistances

 

ORDERING INFORMATION
AC-MER-CONT-2DRAccess Platform EP1502 Door Controller (Mercury EP1502)

ac-mer-con-mr52

 

Single Reader Interface Module

 

 

Avigilon™ Access Control Manager supports open field hardware from Mercury Security allowing organizations to leverage investments in non-proprietary field hardware, with retrofit programs available for industry standard door hardware and card readers, including contact/contactless smart card, proximity, magnetic stripe and barcode.

ac-mer-con-mr52

 

The AC-MER-CON-MR50 is a low cost, high performance, single card reader, interface panel that is capable of all the I/O needed for managing a single (1) controlled opening with Avigilon’s Access Control Manager (ACM). Based on the Mercury Security (MR50), each AC-MER-CON-MR50 will interface one (1) card reader, two (2) generalpurpose input monitor points and two (2) control relays to provide access control andv security monitoring through the AC-MER-CONT-1DR, ACMER-CONT-2DR or the AC-MER-CONT-64DR intelligent controllers. The result is the flexibility, versatility and reliability required for demanding access control solutions. Access Control Manager and Mercury Security open field hardware provide the ultimate platform to complete the Avigilon endto-end security solution.

 

KEY FEATURES

  • Compact footprint and RS-485 connectivity
  • 12 or 24V DC input power support
  • Interfaces with a wide array of reader technologies including Wiegand, clock
  • and data, magnetic stripe and keypads
  • Supports being clustered or distributed to best suit the installation
  • environment
  • Inputs and the output relays support assignment to door related functions or to
  • general purpose I/O
  • Inputs support normally open, normally closed, supervised and nonsupervised circuits
  • Output relays are configurable for fail-safe or fail secure operation

 

Specifications

TECHNICAL SPECIFICATIONS

Primary Power

12-24 V DC +/- 10%, 150mA maximum

12V DC @ 110mA nominal

24V DC @ 60mA nominal

Communication

RS–485, 2-wire, 4,000’ (twisted pair with shield, Belden 9841)

Reader Port 1

Power: Input voltage pass-through Data Card/Keypad Clock/Data, Data–1/Data–0, or RS-485

LED

Two-wire, or one-wire bi-color LED support

Buzzer

Only with ‘one-wire’ LED

Inputs

2 General purpose: Programmable circuit type

1 Dedicated: Tamper

Output Relays

Relay 1: Form–C, 5 Amp 30 VDC

Relay 2: Form–C, 1 Amp 30 VDC

Dimensions

(W x L x H) 108mm x 70mm x 25mm; 4.25” x 2.75” x 1.0”

Temperature

Operating: -40° C to 75° C (-40° F to 167° F)

Storage: -55° C to 85° C (-67° F to 185° F)

 

Humidity

0 – 95% Relative humidity (non-condensing)

Standards

UL 294 Recognized, CE Compliant, RoHS

 

ORDERING INFORMATION

AC-MER-CON-MR50

Access Platform MR50 Single Card Reader Interface (Mercury MR50)

 

 

ac-mer-con-mr52

 

 

Leave a Comment